Technical Product GuideMULTI OUTDOOR UNITSModels:MULTI18HP230V1AOMULTI24HP230V1AOMULTI30HP230V1AOMULTI36HP230V1AOMULTI42HP230V1AO
REFRIGERATION SPECIFICATIONS & DATA9PIPING LENGTH REQUIREMENTSL =L1LTOTAL=L1 + L2 + ...LnL2+ + +LS...LnRefrigerant ChargeRefrigerant Piping Le
10+Multi Outdoor UnitsPIPING HEIGHT REQUIREMENTSL2L1L3...LnH1H2MULTI18HP230V1A 33 ft. 16 ft.MULTI24HP230V1A 66 ft. 25 ft.MULTI30HP230V1A 66 ft.
ELECTRICAL DATA11Outdoor UnitOutdoor UnitOutdoor UnitMULTI18HP230V1A 208/230v-1ph-60hz 187-253 1.7 1.6 MULTI24HP230V1A 208/230v-1ph-60hz 187-25
12DIMENSIONAL SPECIFICATIONSModel No: MULTI24HP230V1A 24,000 BtuHModel No: MULTI18HP230V1A 18,000 BtuHSuction/Gas Line Port Size Port A 3/8-i
13DIMENSIONAL SPECIFICATIONSModel No: MULTI36HP230V1A 36,000 BtuHModel No: MULTI30HP230V1A 30,000 BtuHSuction/Gas Line Port Size Port A 3/8-in O
14DIMENSIONAL SPECIFICATIONS+Multi Outdoor UnitsModel No: MULTI42HP230V1A 42,000 BtuHSuction/Gas Line Port Size Port A 3/8-in OD FlaredPort B
15MINIMUM OUTDOOR CLEARANCE SPECIFICATIONSThe unit installation must meet or exceed the following minimum clearances for proper operation.Air OutletAB
16ELECTRICAL WIRING+Multi Outdoor UnitsThe main power is supplied to the outdoor unit. System must be on a single dedicated circuit. Use appropriate w
17ELECTRICAL WIRINGCONDENSATE REMOVALInstall condensate drain to bottom of outdoor unit to safely and eectively route condensate water to a safe loc
INDOOR UNIT COMBINATIONS+Multi Outdoor UnitsSELECTION CRITERIA When selecting a variable speed system, match the system capacity to the calculated loa
Table of ContentsProduct Overview ...2-3Features and Benefits ...4-5Product Nomenclature/AHRI
19INDOOR UNIT COMBINATIONSModel No: MULTI24HP230V1A 24,000 BtuHCooling Capacity (BtuH)Heating Capacity (BtuH) 9K+9K 18,000 6,824~26,600 9,000
INDOOR UNIT COMBINATIONS+Multi Outdoor UnitsModel No: MULTI30HP230V1A 30,000 BtuHCooling Capacity (BtuH)Heating Capacity (BtuH) 9K+9K 18,000 6
21INDOOR UNIT COMBINATIONSModel No: MULTI30HP230V1A 30,000 BtuH (cont.)Model No: MULTI36HP230V1A 36,000 BtuHHeating Capacity (BtuH)Cooling
22+Multi Outdoor UnitsINDOOR UNIT COMBINATIONSModel No: MULTI36HP230V1A 36,000 BtuH (cont.)Cooling Capacity (BtuH) 12K+12K+12K 29,685 10,236~
INDOOR UNIT COMBINATIONSModel No: MULTI36HP230V1A 36,000 BtuH (cont.)Heating Capacity (BtuH) 9K+9K+12K 27,024 15,354~33,780 7,694 8,069 11
24INDOOR UNIT COMBINATIONS+Multi Outdoor UnitsModel No: MULTI42HP230V1A 42,000 BtuHCooling Capacity (BtuH) 9K+9K 20,472 11,942~30,709 8,530
25INDOOR UNIT COMBINATIONSModel No: MULTI42HP230V1A 42,000 BtuH (cont.)Cooling Capacity (BtuH)Heating Capacity (BtuH) 9K+18K+18K+18K 39,580 1
26INDOOR UNIT COMBINATIONS+Multi Outdoor UnitsModel No: MULTI42HP230V1A 42,000 BtuH (cont.)Heating Capacity (BtuH) 12K+12K+18K 44,357 15,354~
27EXTENDED PERFORMANCE RATINGS 25°F 22,145 16,443 23,936 17,330 25,587 18,422 35°F 21,641 16,423 23,047 16,825 24,167 17,473 45°F 20,572 1
28EXTENDED PERFORMANCE RATINGS+Multi Outdoor Units 25°F 31,988 23,751 34,575 25,032 36,959 26,610 35°F 31,260 23,723 33,291 24,302 34,907 25
Height DierenceBetween Indoor Units:50ftPRODUCT OVERVIEWSUPERIOR DESIGNS PROVIDE EASY SOLUTIONS TO COMPLEX PROBLEMSGREE Ductless Multi Zone systems p
29EXTENDED PERFORMANCE RATINGS 25°F 35,679 26,492 38,564 27,920 41,224 29,681 35°F 34,867 26,460 37,132 27,106 38,935 28,150 45°F 33,144
30+Multi Outdoor UnitsEXTENDED PERFORMANCE RATINGS 25°F 41,830 31,059 45,213 32,734 48,331 34,798 35°F 40,878 31,022 43,534 31,780 45,648 33,004
31EXTENDED PERFORMANCE RATINGS 25°F 49,212 36,540 53,192 38,511 56,860 40,939 35°F 48,092 36,497 51,216 37,388 53,704 38,82
Limited Warranty Statement32GREE distributor (hereinafter “Company”) warrants this product against failure due to defect in materials or workmanship u
33All implied warranties and/or conditions (including implied warranties or conditions of merchantability and fitness for a particular use or purpose)
Specifications in this booklet are subject to change without notice. Manufacturer reserves the right to discontinue or modify specifications or designs
PRODUCT OVERVIEW3Self-Diagnostics SystemEach indoor and outdoor unit continuously runs a series of multi-point diagnostic tests on the system, to auto
High Eciency G-10 InverterThe G-10 Inverter uses a broad range of variable frequencies to drive the compressor, marking the highest level of inverter
FEATURES AND BENEFITS5Low Voltage Start UpHaving stable electrical power is not always an option. The Gree Multi Zone units will operate from 170v to
NOMENCLATURE6AHRI CERTIFICATIONMODEL NUMBER BRAND AHRI CERTIFICATIONMULTI18HP230V1AO GREE 7084754MULTI24HP230V1AO GREE 7084908MULTI30HP230
PERFORMANCE SPECIFICATIONS7HeatingMULTI18HP230V1A 8.2 19,000 (8,530-22,600) 5 °F 80 °FMULTI24HP230V1A 8.2 29,000 (7,500-35,000) 5 °F 80 °
+Multi Outdoor UnitsAIR FLOW DATASOUND DATAPRODUCT WEIGHTMODEL NUMBER MULTI18HP230V1A 1,530 MULTI24HP230V1A 1,530MULTI30HP230V1A 1