Submittal Data: RIO12HP115V1A
12,000 BTU/H Wall Mounted Heat- Pump System
GENERAL FEATURES
-Compact and Quiet Design
-High Efficiency - 16 SEER
-DC Inverter Technology
-Wireless Remote with LCD Display
-Low Ambient Cooling
-Comfortable Sleep Mode
-Intelligent Defrost
-5 year Limited Parts Warranty
-7 year Limited Compressor Warranty
Cooling
Fan Motor
Output Power 10 W
Rated Capacity 11,800 BTU/H FLA 0.4 A
Capacity Range 3,300-12,500 BTU/H
Power Input (Max) 1,340 W
Airflow
Indoor Unit Data
System Ratings
AHRI Certified Ref No: 7084752
Reference Approval
Construction
EER 9.4
Heating Dry (Lo/Hi)
211/341 CFM
Heating at 47° F Sound Pressure Level
Rated Capacity 13,000 BTU/H
Cooling (Lo/Hi)
32/40 db(A)
Capacity Range 3,400-13,500 BTU/H
Heating (Lo/Hi)
32/40 db(A)
Power Input (Max) 1,360 W Dimensions & Weights
HSPF 8.6 Unit Dimensions (LxHxD) 30.3 x 11.1 x 7.9-in
COP 2.9 Weight (Net/Shipping) 19/25 LBS
Heating at 17° F
Rated Capacity 8,500 BTU/H Compressor DC Inverter Driven Rotary
Capacity (Max) 11,110 BTU/H Refrigerant Type R410A
Power Input (Max) 1,162 W Fan Motor Output Power 30 W
COP 2.2 FLA 0.2 A
Sound Pressure
Operating Range
Cooling 55 db(A)
Cooling (Max)
113℉ (45 C) Heating 55 db(A)
(Min)
64℉ (18 C) Dimensions & Weights
Heating (Max)
75℉ (24 C) Unit Dimensions (LxHxD) 33.4 x 21.2 x 12.6 -in
(Min)
5℉ (-15 C) Weight (Net/Shipping) 75/84 LBS
Power Supply Refrigerant Piping Data
Normal Operational Voltage
115 V, 1 Phase, 60 Hz Gas Pipe Size (OD) 3/8-in
Voltage Range
103-127 V Liquid Pipe Size (OD) 1/4-in
Main Power Wire Size
10-2 AWG Connection Method Flared
Interconnecting Cable Wire Size
14-4 AWG MAX Refrigerant Pipe Length 66-ft
MCA
15.0 A MIN Refrigerant Pipe Length 10-ft
MOCP/Breaker Size
25 A MAX Refrigerant Pipe Height Difference 33-ft
Outdoor Unit Data
© Gree Corporation 2014 V3